Arch. cardiol. Méx ; 90(2): 108-115, Apr.-Jun. 2020. tab, graf
Article in English | LILACS | ID: biblio-1131018

ABSTRACT

Abstract Background: Paravalvular leak (PVL) is a frequent and important complication after surgical valvular replacement that can cause heart failure and hemolytic anemia and is associated with poor clinical outcomes. Surgical reoperation has been the standard treatment, but it is associated with high morbidity and mortality. Transcatheter closure is a therapeutic alternative. The aim of the present study is to analyze the feasibility and the short- and medium-term outcomes of the transcatheter closure of PVLs. Methods: Single-center registry of consecutive patients with post-surgical PVLs that underwent transcatheter closure, between January 2006 and December 2016. Efficacy and safety results were analyzed during the procedure and at 6-month follow-up. Results: Twenty-one PVLs (15 mitral, 5 aortic, and 1 tricuspid) were closure during 20 procedures. In the initial echocardiography, 91% of the leaks were severe. The most used device was the Amplatzer Vascular Plug III® in 10 procedures (50%). The three-dimensional transesophageal echocardiography was used in 70% of cases. The device was successfully implanted in 95% of cases, a regurgitation reduction ≥ 1 grade was achieved in 95% of the cases, and the clinical success was 79%. Six-month survival was 100%; however, three cases required valvular surgery (15%). Conclusions: Transcatheter closure of PVLs is a feasible and safe procedure with high rates of technical, echocardiographic, and clinical success in the short and medium term. It is an adequate therapeutic alternative, mainly in high surgical risk patients and multiples comorbidities.


Resumen Introducción: La fuga paravalvular es una complicación frecuente e importante posterior al reemplazo valvular quirúrgico que puede ocasionar insuficiencia cardiaca, anemia hemolítica y se relaciona con malos resultados clínicos. La reintervención quirúrgica ha sido el tratamiento habitual, pero se acompaña de alta morbimortalidad. El cierre transcatéter es una alternativa terapéutica. El objetivo del presente estudio es analizar la factibilidad y los resultados a corto y mediano plazo del cierre transcatéter de fugas paravalvulares con dispositivos oclusores. Métodos: Registro unicéntrico de una serie consecutiva de pacientes con fugas paravalvulares posquirúrgicas que fueron cerradas vía transcatéter con dispositivos oclusores, entre enero del 2006 y diciembre del 2016. Se analizaron los resultados de eficacia y seguridad durante el procedimiento y a seis meses. Resultados: Se trataron 21 fugas paravalvulares (15 mitrales, 5 aórticas y 1 tricuspídea) durante 20 procedimientos. El 91% de las fugas fue grave en la ecocardiografía inicial. El dispositivo utilizado con más frecuencia fue el Amplatzer Vascular Plug III® en 10 procedimientos (50%). Se utilizó ecocardiografía transesofágica tridimensional en 70% de los casos. Se logró implantar el dispositivo con éxito en el 95% de los casos; se consiguió una reducción ≥ 1 del grado de regurgitación en el 95% de las veces y se alcanzó el éxito clínico en el 79%. A seis meses la supervivencia fue del 100%; sin embargo, tres casos requirieron cirugía valvular (15%). Conclusiones: El cierre transcatéter de fugas paravalvulares es un procedimiento factible, seguro y con tasas elevadas de éxito técnico, ecocardiográfico y clínico a corto y mediano plazo. Es una alternativa terapéutica adecuada, en particular en pacientes considerados de alto riesgo quirúrgico y múltiples comorbilidades.


Subject(s)
Humans , Male , Female , Adult , Middle Aged , Aortic Valve Insufficiency/surgery , Tricuspid Valve Insufficiency/surgery , Cardiac Catheterization/methods , Mitral Valve Insufficiency/surgery , Time Factors , Prosthesis Failure , Heart Valve Prosthesis , Registries , Follow-Up Studies , Treatment Outcome , Echocardiography, Transesophageal , Echocardiography, Three-Dimensional , Septal Occluder Device
4.
Arch. cardiol. Méx ; 85(3): 256-258, jul.-sep. 2015. ilus
Article in Spanish | LILACS | ID: lil-767578

ABSTRACT

La fuga paravalvular es una complicación relevante después del cambio valvular quirúrgico. Tradicionalmente la cirugía ha sido considerada el tratamiento de elección, sin embargo, conlleva una elevada morbimortalidad, así como un incremento en el riesgo de desarrollar fuga paravalvular recurrente. El tratamiento percutáneo de la fuga paravalvular se presenta como una atractiva alternativa. Dicho tratamiento ha sido posible por la capacidad actual de integrar múltiples modalidades de imagen que han ayudado a definir la anatomía del defecto y a planificar y guiar el procedimiento de cierre percutáneo, resultando en mejores desenlaces. El Amplatzer® Vascular Plug III (St. Jude Medical) es el primer dispositivo específicamente diseñado para el cierre percutáneo de la fuga paravalvular con resultados prometedores. Presentamos la imagen ecocardiográfica transesofágica tridimensional del resultado exitoso de cierre percutáneo de una fuga paravalvular mitral residual con un dispositivo Amplatzer® Vascular Plug III (St. Jude Medical), después de un procedimiento inicial de cierre percutáneo con un dispositivo Amplatzer® Duct Occluder (St. Jude Medical).


Paravalvular leak is a significant complication after surgical valve replacement. Traditionally, redo surgery has been considered the treatment of choice, but is associated with high morbidity and mortality as well as increase risk of developing new leaks. Percutaneous treatment of paravalvular leak appears as an attractive alternative. Such treatment has been made possible by the current ability to integrate multiple imaging modalities that have helped to define the anatomy of the defect and planning and guiding the percutaneous closure procedure, thus resulting in better outcomes. The Amplatzer® Vascular Plug III (St. Jude Medical) is the first device specifically designed for percutaneous closure of paravalvular leak with promising results. We present the three-dimensional transesophageal echocardiographic images of a successful outcome of percutaneous closure of a residual mitral paravalvular leak with an Amplatzer® Vascular Plug III device (St. Jude Medical), after an initial procedure of percutaneous closure with an Amplatzer® duct occluder (St. Jude Medical).


Subject(s)
Humans , Male , Middle Aged , Echocardiography, Three-Dimensional , Echocardiography, Transesophageal , Heart Valve Prosthesis Implantation , Mitral Valve/surgery , Postoperative Complications/surgery , Postoperative Complications , Septal Occluder Device , Prosthesis Design
5.
Arch. cardiol. Méx ; 84(4): 250-255, oct.-dic. 2014. ilus
Article in Spanish | LILACS | ID: lil-744058

ABSTRACT

Introducción: El cierre percutáneo de la comunicación interauricular es una alternativa al tratamiento quirúrgico. Objetivos: Comunicar los resultados del cierre percutáneo de la comunicación interauricular con el dispositivo Amplatzer®. Método: Se incluyeron los pacientes sometidos a hemodinamia de septiembre de 1997 a diciembre de 2011. Resultados: Se procedió al cierre del defecto en 721 pacientes y en 85 no se cerró por considerarse no apto anatómicamente. El diámetro expandido del defecto fue de 23 ± 6.7 mm (límites, 5-42). Todos los dispositivos se colocaron con éxito. En 15 casos (2.1%) se cambió el dispositivo por considerarse inestable y en 6 (0.8%) se presentó embolización en las primeras 24 h, 4 fueron rescatados y recolocados (éxito final con intención de tratamiento 719/806-89.2%). El control inmediato mostró oclusión completa en 247 pacientes (34.3%), fuga intradispositivo en 395 (54.9%), ligera en 75 (10.4%) y moderada en 2 (0.3%). Se hace seguimiento en 626 pacientes (87.1%) durante 33 ± 27.5 meses, presentándose cefalea en 54 (8.6%), arritmias supraventriculares nuevas en 10 (1.6%), complicaciones en el sitio de punción en 4 (0.6%) y accidente vascular cerebral en uno (0.1%). Conclusión: El diseño del dispositivo Amplatzer® permite el cierre de la comunicación interauricular con una técnica sencilla y con seguridad para el paciente.


Introduction: Percutaneous closure of atrial septal defects is an alternative to surgical treatment. Objectives: We report the results of percutaneous closure of atrial septal defects with the Amplatzer® device. Method: We include patients taken to the catheterization laboratory from September 1997 to December 2011. Results: We proceeded with defect closure in 721 patients and in 85 the defect was considered not suitable for closure. The stretched diameter of the defect was 23 ± 6.7 mm (limits, 5-42). All devices were positioned successfully. In 15 cases (2.1%) the device was changed due to instability and in 6 (0.8%) the device embolized within the first 24 h, 4 were retrieved and repositioned (final success with intention to treat 719/806-89.2%). Immediate control showed complete closure in 247 patients (34.3%), leak through the device in 395 (54.9%), mild residual leak in 75 (10.4%) and moderate in 2 (0.3%). We have follow-up in 626 patients (87.1%) for 33 ± 27.5 months, with headache in 54 (8.6%), new supraventricular arrhythmia in 10 (1.6%), puncture site complications in 4 (0.6%), and stroke in one (0.1%). Conclusion: The design of the Amplatzer® device allows effective closure of atrial septal defects with a simple technique and patient safety.


Subject(s)
Adolescent , Adult , Aged , Child , Child, Preschool , Female , Humans , Infant , Male , Middle Aged , Young Adult , Heart Septal Defects, Atrial/surgery , Septal Occluder Device , Cardiac Catheterization , Cardiac Surgical Procedures/methods , Time Factors
6.
Arch. cardiol. Méx ; 81(1): 26-28, ene.-mar. 2011. ilus
Article in English | LILACS | ID: lil-631995

ABSTRACT

Intracardiac echocardiography (ICE) is a relatively new method of ultrasound images useful during cardiac percutaneous interventional procedures. The first human experience with this method was published in 2000 and, since then, several original trials have enrolled this useful method, proving similar and more useful than transesophageal echocardiography in percutaneous treatment of several congenital cardiopathies, like interatrial communication, permeable oval foramen, mitral stenosis, and atrial fibrillation ablation. In this presentation, we publish a single case report of percutaneous mitral valvuloplasty under ICE guidance.


La ecocardiografía intracardiaca (EIC) es un método relativamente nuevo de imágenes por ultrasonido que utilizamos principalmente durante procedimientos de cateterismo intervencionista. La primera experiencia en seres humanos con este método fue reportada en 2000 y, desde entonces, se han publicado diversos artículos sobre su utilidad como procedimiento de control sustituto de la ecocardiografía transesofágica, en el tratamiento por cateterismo de la comunicación interatrial, comunicación interventricular, foramen oval permeable, estenosis mitral y ablación de fibrilación auricular. En esta ocasión presentamos un caso de estenosis mitral y valvuloplastía percutánea, guiado por EIC.


Subject(s)
Aged , Female , Humans , Balloon Valvuloplasty/methods , Mitral Valve Stenosis/therapy , Mitral Valve Stenosis , Ultrasonography, Interventional
9.
Arch. cardiol. Méx ; 76(2): 163-168, abr.-jun. 2006.
Article in Spanish | LILACS | ID: lil-569148

ABSTRACT

INTRODUCTION: The anatomic changes of the patent ductus arteriosus (PDA) in adult patients, such as aortic aneurysm, calcification, or being short and sometimes friable, could complicate the surgical treatment. The transcatheter occlusion of PDA with different devices is currently accepted as safe and effective. We presented our experience with percutaneous occlusion of PDA in adult patients by means of three different devices. METHODS AND RESULTS: Between January 2000 and March 2005, 53 adult patients (47 women and 6 men) with PDA were treated for occlusion by means of percutaneous procedures. Average age was 25.3 years (Range, 16 to 54.7 years). Three different devices were used, 39 patients with Amplatzer for ductus arteriosus, 1 patient with Amplatzer for muscular interventricular communication, 11 with Gianturco coils, and 1 patient with Nit-Occlud. All devices were implanted successfully. Immediate complete closure was achieved in 31 patients (58.4%), in 20 patients (37.7%) with minimal leakage, and in 2 patients (3.89%) with moderate leak. Previous systolic pulmonary pressure had an average of 37.08 +/- 22.8. mm Hg (Range: 12-138 mm Hg) and went down to 28.75 +/- 10.25 mm Hg (Range: 16-57 mm Hg) with p d x 0.001. The average time follow-up was of 16.8 months (Range: 0.9 to 51.8 months) the occlusion was completed in 100%, in neither patients were observed complications related to implant of the devices. CONCLUSION: Transcatheter closure at PDA in adult patients with different devices is safe and feasible.


Subject(s)
Adolescent , Adult , Female , Humans , Male , Middle Aged , Ductus Arteriosus, Patent , Prostheses and Implants , Cardiac Catheterization , Cross-Sectional Studies , Retrospective Studies , Time Factors
10.
Arch. cardiol. Méx ; 75(3): 320-326, jul.-sep. 2005. ilus, tab
Article in Spanish | LILACS | ID: lil-631893

ABSTRACT

El tratamiento quirúrgico de la comunicación interventricular muscular múltiple con lesiones asociadas e hipertensión arterial pulmonar severa tiene una alta morbilidad y mortalidad. El cierre de estos defectos con dispositivo Amplatzer para comunicación interventricular muscular es una alternativa a la cirugía, evitando la utilización de circulación extracorpórea. Presentamos el caso de una mujer de 38 años de edad con signos de falla cardíaca en clase funcional IV (NYHA), con dos comunicaciones interventriculares de tipo muscular, persistencia de conducto arterioso e hipertensión arterial pulmonar severa, que fueron ocluidos con tres dispositivos Amplatzer específicos para cierre de comunicación interventricular muscular, lográndose disminución importante de la presión pulmonar y mejoría de su clase funcional.


Surgical treatment of multiple muscular ventricular septal defects with associated lesions and severe pulmonary hypertension has a high morbility and mortality. Closure of these defects by the Amplatzer muscular VSD occluder is an alternative to surgery, avoiding the need of cardiopulmonary bypass. We present the case of a 38 year-old woman with signs of heart failure in NYHA functional class IV, with two muscular ventricular septal defects, patent ductus arteriosus and severe pulmonary hypertension, that were treated with three Amplatzer muscular VSD occluders, with significant reduction of pulmonary pressure and functional class improvement.


Subject(s)
Adult , Female , Humans , Ductus Arteriosus, Patent/surgery , Heart Septal Defects, Ventricular/surgery , Hypertension, Pulmonary/complications , Prostheses and Implants , Aortography , Ductus Arteriosus, Patent/complications , Ductus Arteriosus, Patent , Follow-Up Studies , Heart Septal Defects, Ventricular/complications , Heart Septal Defects, Ventricular , Prosthesis Implantation , Time Factors , Treatment Outcome
11.
Arch. Inst. Cardiol. Méx ; 67(3): 210-6, mayo-jun. 1997. ilus, tab
Article in Spanish | LILACS | ID: lil-217299

ABSTRACT

Se realizó un análisis retrospectivo de pacientes menores de 18 años con atresia tricuspídea y concordancia ventrículo-arterial, sometidos a cirugía de Fontan en el Instituto Nacional de Cardiología "Ignacio Chávez" entre enero de 1989 y diciembre de 1995. En el periodo analizado, fueron intervenidos 22 pacientes siendo 14 del sexo femenino con un promedio de edad de 6.52 ñ 1.4 años: Trece pacientes tenían cirugía paliativa previa. La edad en que se practicó fue 10 ñ 12 meses, transcurriendo entre ésta y la cirugía de Fontan 5 ñ 2 años. La mortalidad global fue del 31 por ciento (7 pacientes): de 1989 a 1992 fue del 42 por ciento; entre 1992 y 1995 del 22 por ciento y a partir de 1994 del 17 por ciento, no habiendo mortalidad en los 5 casos operados en 1995. La presión pulmonar media fue de 13.9 ñ 4.15 mmHg, las resistencias pulmonares de 1.66 ñ 0.57 UW m², la presión diastólica final de ventrículo izquierdo 7.5 ñ 2.46 mmHg, la fracción de expulsión de 58 ñ 11 por ciento y los índices de Nakata y McGoom de 219 ñ 56 mm² y 2 ñ 0.1, respectivamente. No se encontraron diferencias, estadísticamente significativas, entre el grupo de sobrevivientes y el de fallecidos, con excepción en la presión diastólica del ventrículo izquierdo en que se obtuvo una p< 0.05. Las causas de muerte fueron: falla orgánica múltiple en 2; fibrilación ventricular en 3 y choque séptico en 2


Subject(s)
Humans , Male , Female , Child, Preschool , Thoracic Surgery/methods , Retrospective Studies , Tricuspid Atresia/surgery